Technical Performance Analysis of a 1 MWp Grid-Connected Photovoltaic System in Pangkalan Kerinci, Indonesia Using PVsyst Simulation
Abstract
The increasing demand for clean energy in Indonesia has accelerated the deployment of grid-connected photovoltaic (PV) systems. This study presents a technical performance analysis of a 1 MWp grid-connected PV system located in Pangkalan Kerinci, Indonesia, using the PVsyst v7.4.6 simulation software. The system comprises 1818 Trina Solar TSM-DE19-550Wp modules mounted on a fixed-tilt structure (2.2° tilt, 180° azimuth) with two SMA Sunny Central 400 MV-11 inverters (DC/AC ratio = 1.25). Meteorological data from Meteonorm 8.1 (1996–2015) was used to simulate annual irradiation and system output. The results show an annual energy production of 1,404,124 kWh, corresponding to a specific yield of 1,404 kWh/kWp/year. The Performance Ratio (PR) reached 82.75%, indicating high system efficiency under tropical climatic conditions. Loss analysis revealed that thermal losses (9.36%) and IAM losses (2.58%) were the dominant factors, while inverter losses accounted for 2.86%. Module mismatch and wiring losses were minimal at 2.15% and 1.5%, respectively. The high PR and low degradation assumptions confirm the suitability of the selected configuration for equatorial regions. This study provides a robust technical benchmark for similar PV installations in Sumatra and supports optimal design decisions for future utility-scale solar projects in Indonesia.
Keywords
Full Text:
PDFReferences
REI, “Kebijakan Energi Terbarukan dan Kedudukan Energi Terbarukan di Indonesia Saat Ini,” https://renewableenergy.id/kebijakan-energi-terbarukan/.
B. Hashemi, S. Taheri, A.-M. Cretu, and E. Pouresmaeil, “Systematic photovoltaic system power losses calculation and modeling using computational intelligence techniques,” Appl Energy, vol. 284, p. 116396, Feb. 2021, doi: 10.1016/j.apenergy.2020.116396.
M. Dhimish, “Thermal impact on the performance ratio of photovoltaic systems: A case study of 8000 photovoltaic installations,” Case Studies in Thermal Engineering, vol. 21, p. 100693, Oct. 2020, doi: 10.1016/j.csite.2020.100693.
P. U. Poornima et al., “Optimising rooftop photovoltaic adoption in urban landscapes: A system dynamics approach for sustainable energy transitions,” Biomed Signal Process Control, vol. 100, p. 107071, Feb. 2025, doi: 10.1016/j.bspc.2024.107071.
H. O. Njoku, “Solar Photovoltaic Potential in Nigeria,” Journal of Energy Engineering, vol. 140, no. 2, Jun. 2014, doi: 10.1061/(ASCE)EY.1943-7897.0000145.
N. Anang, S. N. A. Syd Nur Azman, W. M. W. Muda, A. N. Dagang, and M. Z. Daud, “Performance analysis of a grid-connected rooftop solar PV system in Kuala Terengganu, Malaysia,” Energy Build, vol. 248, p. 111182, Oct. 2021, doi: 10.1016/j.enbuild.2021.111182.
Y. N. Chanchangi, A. Ghosh, S. Sundaram, and T. K. Mallick, “Dust and PV Performance in Nigeria: A review,” Renewable and Sustainable Energy Reviews, vol. 121, p. 109704, Apr. 2020, doi: 10.1016/j.rser.2020.109704.
P. M. Sivaram, A. B. Mande, M. Premalatha, and A. Arunagiri, “Investigation on a building-integrated passive solar energy technology for air ventilation, clean water and power,” Energy Convers Manag, vol. 211, p. 112739, May 2020, doi: 10.1016/j.enconman.2020.112739.
DOI
https://doi.org/10.21107/ijseit.v10i1.32479Metrics
Refbacks
- There are currently no refbacks.
Copyright (c) 2026 Dedi Tri Laksono, Deni Tri Laksono, Monika Faswia Fahmi, Rien Afrianti, Nofri Dodi

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.